Sign In | Join Free | My ccnmag.com
China Guangzhou Chunke Environmental Technology Co., Ltd. logo
Guangzhou Chunke Environmental Technology Co., Ltd.
Guangzhou Chunke Environmental Technology Co., Ltd. Email: jessieli@gzchunke.com Whatsap/Phone number : +86 17502033136
Active Member

7 Years

Home > EDI Water Treatment Plant >

Ultra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kw

Guangzhou Chunke Environmental Technology Co., Ltd.
Contact Now

Ultra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kw

  • 1
  • 2
  • 3

Brand Name : Chunke

Model Number : CH-EDI

Certification : ISO9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiable

Payment Terms : Cash,PayPal, T/T, L/C, Western Union

Supply Ability : 1000 unit per month

Delivery Time : 7-10 days

Packaging Details : Standard package

Name : Ultra Pure Water Treatment RO EDI and Polishing Resin System for Purification

Usage : Ultra Pure Industrial Water

Control : PLC control

Warranty : 12 months

Power : 0.75-15kw

Driven Type : Electric

Fuction : Purifying

Contact Now

Ultra Pure Water Treatment RO EDI and Polishing Resin System for Purification

Incoming water quality control

(1) control of water inlet conductivity.Strictly control the conductivity in the pretreatment process, make EDI water conductivity less than 40 S/cm, can ensure the qualified conductivity of the water and the removal of weak electrolyte.

(2) control of operating voltage and current.When the system works, the appropriate operating voltage and current shall be selected.At the same time, there is a position of limit voltage-current point on the voltage-current curve of EDI water purification equipment, which is related to factors such as water quality, performance of membrane and resin and membrane pair structure [4].In order to generate enough H+ and OH- ions from a certain amount of water and electricity to regenerate a certain amount of ion exchange resin, the voltage-current operating point of selected EDI water purification equipment must be greater than the limit voltage-current point.

(3) control of inlet CO2.The pH can be adjusted by adding alkali before RO to remove CO2 to the maximum extent, and CO2 can also be removed by degassing tower and degassing film.

(4) water hardness control.The RO water can be softened and alkali added in combination with CO2 removal.When the salt content of water is high, RO or nf can be added by combining with desalting.

(5)TOC control.In combination with other index requirements, add a RO to meet the requirements.

(6) control of turbidity and pollution index.Turbidity and pollution index are one of the main indexes for inlet water control of RO system. Qualified RO outlet water can generally meet the inlet water requirement of EDI.

(7) control of Fe.Fe controlling EDI water intake during operation is lower than 0.01Mg/L.If the resin has occurred "poisoning", you can use acid solution for resuscitation treatment, the effect is better.[1]

(8) EDI system inlet water quality requirementsBased on the analysis of the above aspects, the water quality requirements for EDI inlet are shown in the table, so that the effluent index can meet the requirements of high pure water required by semiconductor manufacturing in the electronic industry.

Application service

EDI technology is widely accepted by pharmaceutical industry, microelectronics industry, power generation industry and laboratory.It is widely used in surface cleaning, surface coating, electrolysis industry and chemical industry.Yr-edi water inlet requires that the total exchangeable cation (including Co2) < 25mg/L (calculated by CaCo3) PH value 5-9 hardness (calculated by CaCo3) < 0.1 < 0.5 < 0.75 < 1.0 recovery rate 95% 90% 85% 80% active Sio2 < 0.5mg/L total organic carbon (TOC) < 0.5mg/L free oxygen < 0.5mg/L15 7.2 GPM (1.6 to 3.4 m3 / h) in normal temperature is 80-95% of 40-100 ° F (5 to38 ° C) inlet pressure 45-100 psi (3.1 to 6.8 Bar) input voltage 600 VDC (maximum) power consumption 0.32 0.66 KW. 12 h/m3 dimension "Wx24 Hx19 D 300 mmwx610mmhx (90 MMD

EDI system Technical Specification

Model

Capacity

(T/H)

Power

(KW)

Recovery

(%)

One stage

finished water

conductivity

Two stage

finished water

conductivity

EDI system

finished water

conductivity

Raw water

conductivity

RO-500 0.5 0.75 55-75

≤10

2-3

≤0.5

≤300

RO-1000 1.0 2.2 55-75
RO-2000 2.0 4.0 55-75
RO-3000 3.0 5.5 55-75
RO-5000 5.0 7.5 55-75
RO-6000 6.0 7.5 55-75
RO-10000 10.0 11 55-75
RO-20000 20.0 15 55-75

EDI system More Pictures

Ultra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kwUltra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kwUltra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kw


Product Tags:

ro edi plant

      

edi water treatment system

      
China Ultra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kw wholesale

Ultra Pure EDI Water Treatment System / Seawater Desalination Plant 0.75-15kw Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Chunke Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)